Mass flowmeters – Coriolis flow measurement for liquids and gases

Coriolis mass flowmeters provide precise and direct measurement of mass flow in liquids and gases and can simultaneously measure, among other things, density and temperature. Fagerberg offers KROHNE mass flowmeters for both small dosing flows, large flow quantities and demanding applications with, for example, high pressure, high temperatures, viscous media or entrained gas.

Mass flow meter | Coriolis flow measurement | Fagerberg

What is a Coriolis mass flowmeter?


A mass flowmeter measures the mass flowing through the pipe – for example in kg/h or t/h – rather than measuring only volumetric flow.

The Coriolis principle makes it possible to measure mass flow directly without first having to calculate it from volume and density. This makes the measurement principle suitable for processes where precise dosing, process control or billing is important.

How the Coriolis principle works


In a Coriolis mass flowmeter, one or more measuring tubes are set into controlled oscillations. When the medium flows through the tubes, the mass motion affects the oscillation. Sensors register the displacement between the tubes' movements, and this displacement is used to determine the mass flow.

The meter can simultaneously determine the medium's density from the measuring tube's resonance frequency and record the temperature. In this way, the same instrument can deliver multiple process values.

What can a Coriolis mass flowmeter measure?


Depending on the instrument and application, a Coriolis meter can be used for:

  • direct mass flow
  • density
  • temperature
  • calculated volumetric flow
  • total mass and volume
  • concentration measurement in selected processes

This makes Coriolis technology relevant when there is a need for more information about the process than the flow amount alone.

Benefits of Coriolis mass flow measurement


Coriolis is a versatile measurement principle that can be applied to both liquids and gases and to many different process conditions.

The benefits include:

  • direct measurement of mass flow
  • high measurement accuracy
  • simultaneous measurement of density and temperature
  • possibility of calculating volume flow
  • measurement of both liquids and gases
  • suitable for dosing, batching and process control
  • solutions for both very small and very large flows
  • solutions for viscous, aggressive and demanding media

Selected KROHNE OPTIMASS meters also feature Entrained Gas Management (EGM™), which makes it possible to maintain measurement when air or gas is present in the liquid.

Mass flow meter | Coriolis flow measurement | Fagerberg

KROHNE mass flow meters for various applications


KROHNE's range of Coriolis mass flow meters spans from compact meters for very small flows to solutions for large industrial flow quantities. The choice depends among other things on flow range, medium, pressure, temperature, viscosity and accuracy requirements.

Mass flow meter | Coriolis flow measurement | Fagerberg

OPTIMASS 1000 – for general flow tasks


KROHNE OPTIMASS 1000/1400 is a Coriolis mass flowmeter with two straight measuring tubes for a wide range of standard applications with liquids and gases.

It is an obvious starting point for general process measurement where a reliable and cost-effective Coriolis solution is desired. The meter is available in DN15-DN50 and features EGM™ for liquid with entrained air or gas.

See KROHNE OPTIMASS 1000

OPTIMASS 2000 – for very large flow quantities


KROHNE OPTIMASS 2000/2400 is designed for large mass flows and is available in sizes from DN100 to DN400.

The meter is particularly suitable for bunkering and billing applications within oil and gas as well as industrial applications with large quantities such as chemicals, syrup and molasses.

See KROHNE OPTIMASS 2000

OPTIMASS 3000 – for small flow and precise dosing


KROHNE OPTIMASS 3000/3400 is developed for demanding low-flow and dosing applications.

The metre can be used for flow from approximately 0.3 kg/h and is therefore relevant where even small quantities must be registered precisely. It can also be used at high process pressures.

See KROHNE OPTIMASS 3000

OPTIMASS 6000 – for demanding process conditions


KROHNE OPTIMASS 6000/6400 is a high-performance Coriolis mass flow metre for demanding process and billing applications.

It can be used in petrochemicals, oil and gas as well as food and beverage industries and is available in versions for cryogenic media down to -200 °C, high temperatures up to 400 °C and pressures up to 200 barg.

See KROHNE OPTIMASS 6000

Mass flow meter | Coriolis flow measurement | Fagerberg
Mass flow meter | Coriolis flow measurement | Fagerberg

OPTIMASS 7000 – for viscous and demanding media


KROHNE OPTIMASS 7000/7400 is particularly suitable for demanding measurement tasks with, amongst other things, gas, highly viscous liquids, sludge, aggressive media and low flow.

The metre is available with different materials in the media-contacting parts and has EGM™ for applications where air or gas may be present in the liquid.

See KROHNE OPTIMASS 7000

OPTIBATCH 4011 – for filling and batching


KROHNE OPTIBATCH 4011 is designed for batching and filling processes with conductive and non-conductive liquids.

The fully welded design and the option of various hygienic process connections make the metre particularly relevant for the food, beverage and pharmaceutical industry.

See KROHNE OPTIBATCH 4011

Mass flow measurement for different applications


Coriolis mass flow metres are used in many different processes, because the same measurement principle can be used for both liquids and gases and at the same time provide information about, amongst other things, mass flow, density and temperature.

Dosing and batching


When dosing and batching, it is important to know the actual amount of product being fed into the process.

Coriolis mass flow measurement is therefore well suited for, amongst other things, dosing of ingredients, chemicals and concentrates as well as for automatic filling and batch processes. For very small flows, a solution such as OPTIMASS 3000 may be relevant, whilst OPTIBATCH is developed specifically for filling processes.

Food and pharma


In the food and pharmaceutical industry, mass flow measurement can be used for, amongst other things, dosing, mixing, batching and concentration measurement.

KROHNE offers both Coriolis meters with hygienic process connections and solutions for processes with varying density, viscosity or entrained air and gas.

Chemicals and process industry


When measuring chemicals and process fluids, the flow meter must be selected based on both the medium's properties and the process conditions.

Coriolis meters can be used for, amongst other things, aggressive, viscous and high-temperature media, but correct selection of meter tube material, size and process connection is crucial.

Oil, gas and marine


The Coriolis principle is also used for fuel, oil, gas, bunkering and billing applications.

Here, direct mass flow can be an advantage, because the measurement is based on the actual mass rather than a volume, which can change with, amongst other things, temperature and density.

Mass flow meter | Coriolis flow measurement | Fagerberg

Liquids with entrained air or gas


Gas bubbles in a liquid can pose challenges for traditional Coriolis metres, as they affect the vibrations of the measuring tube.

Selected KROHNE mass flowmeters use EGM™, which tracks changes in vibrations and makes it possible to maintain measurement even when gas or air is present in the liquid. This can be relevant in food and process applications, amongst others.

How to choose the right mass flow meter


The existing pipe dimension is not necessarily the correct size for a Coriolis mass flow meter. To select and size the meter correctly, the actual process conditions should be assessed.

Flow range and sizing


Minimum, normal and maximum flow are key information for sizing.

An oversized meter can mean that the process is far down in the instrument's measurement range, while an undersized meter can result in unnecessary pressure drop or high flow velocity.

Medium, density and viscosity


The density and viscosity of the medium are important for sizing, pressure drop and meter selection.

For gas measurement, additional process data is also required to correctly size the solution.

Pressure and temperature


Process pressure and temperature should always be included in the selection of mass flow meter.

KROHNE's OPTIMASS programme includes both solutions for common process conditions and special versions for very high pressures, cryogenic temperatures and high-temperature processes.

Material selection


The material of the parts in contact with the medium must be compatible with the process medium.

This is particularly important for Coriolis meters, as the meter tubes are relatively thin-walled. Material selection should therefore be made on the basis of the instrument manufacturer's recommendations and the specific application.

Mass flow meter | Coriolis flow measurement | Fagerberg

Mass flow measurement in practice


See examples of how Coriolis mass flowmeters are used in concrete process installations.

Mass flow meter | Coriolis flow measurement | Fagerberg

Mass flowmeters optimise process flow in enzyme production


At Novozymes in Kalundborg, KROHNE OPTIMASS 6400 mass flowmeters are used in a process facility for enzyme production.

The meters with EGM™ are part of a solution where the objectives included more stable operation, faster start-up and more precise dosing.

Read the case about mass flow measurement in enzyme production

Redundant mass flow measurement ensures precise dosing


In another application at Novozymes, two KROHNE OPTIMASS 7000 units are used in series to measure enzyme concentrate.

The redundant system was chosen due to high requirements for reproducibility and precision as well as the need to handle products that may contain air and gas bubbles.

Read the case about redundant mass flow measurement

Get help selecting and sizing a mass flow meter

The right mass flow meter depends on much more than pipe size.

Tell us about the medium, flow range, pressure, temperature and your specific measurement task. Our specialists will then help you assess and size a Coriolis mass flow meter for your process conditions.

When should you choose a different flow principle?


Coriolis is not necessarily the best choice for all flow tasks. The choice depends, amongst other things, on the medium, pipe dimension, desired accuracy, pressure drop, installation and which process values need to be measured.

A magnetic inductive flow metre can, for example, be relevant for conductive liquids, while ultrasonic flow measurement can be interesting for large pipe dimensions or where clamp-on measurement is desired without intervention in the pipe.

Vortex flow metres are used, amongst other things, for steam, liquids and gases, while rotameters can be a simple solution for local flow display in less demanding applications.