Limit switches
Limit switches provide feedback about the valve position. When the valve is open, closed or in an end position, the switch sends a signal to the control room, PLC, SCADA system or other control system. At Fagerberg you will find limit switches and switchboxes for pneumatic actuators, valves and industrial automation tasks. We help you choose a solution based on valve type, actuator, contact principle, environment, signal requirements and requirements for ATEX or SIL.
What is a limit switch?
A limit switch is a component that detects and reports whether a valve has reached its predetermined position. It is typically used to confirm whether the valve is open, closed or in an intermediate position, so the control system not only sends a command but also receives feedback on the valve's actual position.
On automated valves, limit switches are often mounted together with pneumatic actuators, electric actuators or directly on the valve stem. The solution can be mechanical, inductive or integrated in a switchbox, where contacts and terminals are protected in a housing.
A switchbox is often used when there is a need for a robust and integrated solution for position feedback on valves in industry, utilities, energy, wastewater and process plants.
When do limit switches make sense?
Limit switches are relevant when you need safe position feedback on a valve. This can be in systems where the valve is controlled automatically, where the valve is located in a difficult-to-access place, or where it is important to be able to document whether the valve has actually reached its position.
They are used for, amongst other things:
- feedback on open/closed valves
- position feedback from pneumatic actuators
- integration with PLC, SCADA or control room
- process systems where valve position must be monitored
- applications with requirements for visual position indication
- installations with ATEX or SIL requirements
- valves where incorrect position can affect operation or safety
A limit switch is particularly important when it is not enough to know that a signal has been sent to the actuator. You also need to know whether the valve has actually moved to the desired position.
When is a limit switch necessary?
A limit switch is necessary when the system needs to document the actual position of the valve. This is especially true in automated processes, where an open or closed valve matters for operation, safety, dosing, flow direction or sequence control.
In simple manual installations, a limit switch may be optional. But as soon as the valve is part of a control system, a safety function or a process where a wrong position can cause operational downtime, spillage or risk to the system, position feedback should be used.
How to choose the right limit switch
The right limit switch depends on both valve, actuator, signal requirements and environment. At Fagerberg you will find both inductive limit switches, mechanical switchboxes and robust limit switch boxes for position feedback on valves.
Contact Principle
Limit switches can be mechanical, inductive or magnetic. Mechanical contacts are a simple and well-known solution for many standard tasks. Inductive limit switches, such as Inductive Limit Switch PF, are contactless and relevant when you want detection without mechanical contact. Magnetic solutions can be applicable where contactless detection and compact design are important parameters.
Actuator and Valve Type
The limit switch must be compatible with the actuator or valve on which it is to be mounted. Some solutions are designed for pneumatic actuators, while others can be used for both rotary and linear applications.
For pneumatic actuators, Inductive Limit Switch PF can be used for both 90° and 180° rotary actuators. Norbro J Switchbox is a mechanical feedback box for Norbro pneumatic actuators, while Flowserve PMV Switchbox can be configured for both rotary and linear solutions.
Signal and Feedback
It is important to clarify what signal the PLC, SCADA system or control room should receive. Some applications require only simple open/closed feedback, while others need multiple contact options, transmitter function, visual indication or 4-20 mA signal. Flowserve PMV Switchbox is relevant when you need a more complete signal box with multiple contact types and signal options. Rotork Soldo Limit Switch Box is a good choice when you need a compact and robust limit switch box for clear position feedback.
Surroundings and enclosure class
Limit switches can be exposed to moisture, dust, temperature fluctuations, vibrations or outdoor placement. Here you should choose a solution with the right enclosure and material quality.
Flowserve PMV Switchbox is available in different materials and variants for demanding environments. Rotork Soldo Limit Switch Box is available in aluminium and stainless steel versions among others and is supplied with flexible brackets so it can be adapted to different installation requirements.
ATEX, SIL and approvals
In explosion-hazardous areas or safety-critical installations, the limit switch must be selected according to the relevant approvals. Here you should clarify zone classification, signal type, contact type and documentation requirements.
Several solutions can be supplied in variants for demanding installations. Flowserve PMV Switchbox may be relevant, for example, when ATEX, Ex d, intrinsically safe or SIL 3 are part of the specification requirements.
Should you choose a limit switch or switchbox?
Are you unsure which solution suits your valve and actuator? We help you choose the right limit switch or switchbox based on signal type, contact principle, enclosure class, ATEX requirements and your need for safe position feedback in your system.
Limit switches as part of a complete actuator solution
Limit switches are often used together with other components for automated valve control. If you need the valve actuation itself, you can see our selection of actuators, pneumatic and hydraulic actuators and electric actuators. For pneumatic solutions, solenoid valves can be used to control the air supply, whilst positioners are used when the valve needs to be controlled more precisely.
We help you assemble the right solution so that actuator, limit switch, switchbox, signal type and control fit together.
FAQ on limit switches
What is a limit switch used for?
A limit switch is used to register and report the valve's position. It typically sends a signal indicating whether the valve is open, closed or in a specific end position, so a control room or control system can monitor the valve's actual status.
What is the difference between a limit switch and a switchbox?
A limit switch is the actual contact function that registers the position. A switchbox or feedback box is an assembled unit that often contains contacts, terminals, visual indication and enclosure. In practice, the terms are often used closely together when discussing position feedback on valves.
Should I choose a mechanical or inductive limit switch?
It depends on the application. A mechanical limit switch is a simple and well-known solution for many standard tasks. An inductive limit switch registers without mechanical contact and may be relevant when you want contactless sensing, less wear and stable feedback from a pneumatic actuator.
Can limit switches be used in ATEX areas?
Yes, but the solution must be selected according to zone classification and the specific requirements of the installation. Several limit switches and switchboxes can be supplied in ATEX variants, and we help clarify which solution suits the actuator, signals and safety requirements.