Solenoid valves for pneumatic actuators | Parker

Solenoid Valves

At Fagerberg you will find Parker solenoid valves and accessories for pneumatic actuators. The solutions can be used for NAMUR mounting directly on the actuator or for separate mounting in the installation. We will help you choose a solenoid valve based on actuator function, voltage, mounting and any ATEX requirements.

Solenoid valves for pneumatic actuators | Parker

What is a solenoid valve?


A solenoid valve is an electrically controlled valve that opens, closes or changes the direction of a control medium. In valve automation, solenoid valves are typically used to convert an electrical signal into a pneumatic movement.

When the solenoid valve receives a signal from the controller, it sends compressed air to the actuator. The actuator then moves the process valve so that it opens or closes.

This makes the solenoid valve an important part of the overall actuator solution when valves are to be remotely controlled, automated or connected to a PLC system, control cabinet or process plant.

On this page you will find Parker solenoid valves and accessories for pneumatic actuators – including solutions with NAMUR connection, various coil voltages, plugs and complete valve packages.

When does a solenoid valve make sense?


A solenoid valve is relevant when an actuator needs to be controlled automatically as part of the system's operation. This applies, among other things, to on/off functions, remote control and applications where the valve needs to respond quickly and reliably to an electrical signal. The choice depends, among other things, on the actuator's design, connection, voltage and the requirements placed on operational safety and the environment. This is also where ATEX and SIL requirements can influence the choice of solution.

Solenoid valves for pneumatic actuators | Parker
Solenoid valves for pneumatic actuators | Parker

Parker solenoid valves


Parker Lucifer 5/2 solenoid valve is a pilot-operated spool valve for pneumatic actuators. It is designed for direct installation on NAMUR interface and can be used as part of a compact actuator solution.

The valve has an aluminium body, internal parts in stainless steel and NBR sealing. It has 1/4" air connection and can be used at ambient temperature from -10 to +50 °C.

The Parker solution can be selected as the solenoid valve itself, as a coil, as a plug or as a complete solenoid valve package with coil and plug. This makes it easier to choose the variant that suits the voltage, installation and service requirements.

Would you like to know more about solenoid valves?

Do you have questions about solenoid valve selection, NAMUR connection or the interaction between solenoid valve and actuator? We are happy to help you find a reliable solution that fits your application and the requirements for control, installation and approvals.

3/2 or 5/2 solenoid valve?


The choice between 3/2 and 5/2 depends on the actuator and the function the solenoid valve is to control.

A 3/2 solenoid valve is typically used for single-acting pneumatic actuators, where the actuator has spring return. The solenoid valve controls the air supply in one direction, whilst the spring provides the return movement.

A 5/2 solenoid valve is typically used for double-acting pneumatic actuators, where air controls movement in both directions. Here the solenoid valve sends air to one or the other side of the actuator, so the process valve can open and close in a controlled manner.

If you are unsure which function to choose, you should first clarify whether the actuator is single-acting or double-acting, and whether the installation requires spring return, pneumatic return or a specific safety position.

Solenoid valves for pneumatic actuators | Parker
Solenoid valves for pneumatic actuators | Parker

NAMUR connection or wall mounting?


Solenoid valves can be mounted directly on the actuator or placed separately, depending on the installation.

Direct mounting with NAMUR connection is relevant when the solenoid valve should sit compactly on the actuator. This provides a simple solution with a short air path between solenoid valve and actuator.

Separate mounting can be relevant when the solenoid valve should be placed in a cabinet, closer to the control unit or in a location where it is easier to service. It can also be an advantage if the environment around the valve places special requirements on access, protection or cable routing.

Coil Voltage


The coil voltage must match the system's control. Parker solenoid valves can be supplied with different coil voltages, so the solution can be adapted to the current installation.

It is important to clarify the voltage before selecting the solenoid valve. Typical conditions that should be checked are whether the system uses AC or DC, what voltage the control supplies, and whether there are any special requirements for connectors, cables or mounting.

If you are replacing an existing solenoid valve, the coil voltage, connection, valve function and mounting type should be checked before selecting a new variant.

Solenoid valves for pneumatic actuators | Parker
Solenoid valves for pneumatic actuators | Parker

ATEX and safety


In some installations, the solenoid valve must be able to be used in areas with explosion risk. Here, ATEX variants may be relevant.

If the solenoid valve is to be installed in an ATEX area, zone classification, voltage, installation, ambient temperature and documentation requirements should be clarified before the solution is selected.

How to choose the right solenoid valve


When choosing a solenoid valve for a pneumatic actuator, you should in particular look at the actuator's function, mounting form, coil voltage and environment.

What you need to clarify What you should look at
Actuator function Is the actuator single-acting or double-acting? This determines whether a 3/2 or 5/2 function should typically be chosen.
Mounting Should the solenoid valve be mounted directly on the actuator with NAMUR, or should it be placed separately in the installation?
Voltage Should the solution use AC or DC, and which coil voltage suits the control system?
Environment Is there moisture, dust, vibration, temperature requirements or ATEX conditions?
Accessories Do you need the solenoid valve itself, a coil, a connector or a complete valve package?