Få et tilbud
Krohne DN100 Optiflux 2100W PP 5 meter 4-20mA output + puls powersupply 230VAC W&W
V091068
Optiflux 2000 er en magnetisk induktiv flowmåler til standard vand- og spildevandsapplikationer udført i robust flange design.
Flowmåleren er den ideelle løsning til flowapplikationer, hvor der kræves pålidelig flowmåling med tilstrækkelig, men ikke ekstrem høj nøjagtighed. Installation i målebrønde udsat for (konstant) oversvømmelse er mulig med IP68 beskyttelse.
Få hjælp her - kontakt mig

Troels Sejer Johansen
tsj@fagerberg.dk | |
Tlf | +45 43290231 |
Produktbeskrivelse
VN144: OPTIFLUX 2100W Flow sensor
B: Nominal diameter: DN 100 | 4"
3: Nominal pressure: PN 16 EN 1092-1
0: Ex-approval_S: non Ex
6: System design / cable connection: Separate with aluminum connection box / M20 x 1.5
4: Converter model: IFC 100 W ( wall mount version )
0: Lining: Standard - PolyPropylene
B: Electrodes ( fixed): Hastelloy C22
1: Construction of electrodes: Fixed
1: Housing- / flange material: Steel / steel St 37-C22 / A 105
0: Protection class / dimension: IP 66 / 67 / standard
0: Cable: separate DS
0: Cable length: 5m
0: Calibration: Standard
6: Ring / -material: Ring #1 / 1.4404|316 L
0: Finish: KROHNE standard
0: none
0: Construction requirements: Standard
0: QA / QC requirements: Standard
0: none
0: Ratio of CT-calibration: Standard, R=80
0: none
0: none
0: Destination Standard
--------
VN314: Signal converter IFC 100
N: Type: IFC 100 W
A: Power supply: 100 - 230 V AC
0: Ex-approval_C: Without - non Ex
6: Cable connection: M20 x 1,5
B: Operating manual / Operating language: Without / northern europe group ( GB,
DK, FI, LT, NO, PL, EE & LV )
0: Custody transfer: Without
D: Process diagnostics: Empty pipe detection
1: Converter housing: Standard
0: none
1: Communication: Basic IO ( 4-20 mA / HART + pulse / frequency + status )
0: 1-st IO Module: Without, no module possible
0: 2-nd IO Module:
0: Reference Method Standard
0: Tagplate: Standard
3: Quick Start language English
***ICF 016005928***
B: Nominal diameter: DN 100 | 4"
3: Nominal pressure: PN 16 EN 1092-1
0: Ex-approval_S: non Ex
6: System design / cable connection: Separate with aluminum connection box / M20 x 1.5
4: Converter model: IFC 100 W ( wall mount version )
0: Lining: Standard - PolyPropylene
B: Electrodes ( fixed): Hastelloy C22
1: Construction of electrodes: Fixed
1: Housing- / flange material: Steel / steel St 37-C22 / A 105
0: Protection class / dimension: IP 66 / 67 / standard
0: Cable: separate DS
0: Cable length: 5m
0: Calibration: Standard
6: Ring / -material: Ring #1 / 1.4404|316 L
0: Finish: KROHNE standard
0: none
0: Construction requirements: Standard
0: QA / QC requirements: Standard
0: none
0: Ratio of CT-calibration: Standard, R=80
0: none
0: none
0: Destination Standard
--------
VN314: Signal converter IFC 100
N: Type: IFC 100 W
A: Power supply: 100 - 230 V AC
0: Ex-approval_C: Without - non Ex
6: Cable connection: M20 x 1,5
B: Operating manual / Operating language: Without / northern europe group ( GB,
DK, FI, LT, NO, PL, EE & LV )
0: Custody transfer: Without
D: Process diagnostics: Empty pipe detection
1: Converter housing: Standard
0: none
1: Communication: Basic IO ( 4-20 mA / HART + pulse / frequency + status )
0: 1-st IO Module: Without, no module possible
0: 2-nd IO Module:
0: Reference Method Standard
0: Tagplate: Standard
3: Quick Start language English
***ICF 016005928***
Nettovægt
15.9
Tarifnummer
90261021
Fabrikkens varenummer
VN144B30640B1100006000000000 + VN314NA06B0D10100003